百媚导航

architecture - engineering - construction
百媚导航
  News  

Rollback Gate Safety System

 
  Subscribe to FREE newsletter  Apr 10, 2017

Meets OSHA Requirements: 1910.23(c) and ANSI 6.4.3

A free standing version of our popular Rollback Bay gate to protect workers on elevated access points for material transfer. Easy-to-use and install. Protects without hindering productivity. Two-gate system means one gate is always closed and OSHA compliant fall protection is in place.

Features

  • Prevents falls from elevated access loading points while transferring material loads.
  • Heavy duty chains and roller tracks ensure long life and smooth operation.
  • Counteracting gates create a safe zone for loading/unloading areas
  • When inboard gate is opened, leading edge gate automatically closes.
  • Adjustable rails to accommodate unforeseen job site conditions.
  • Models available to accommodate single or multiple pallet loading.

Specifications

Outside Dimensions
Description聽Pallet Capacity**听尝听奥H
301348-6060(1) wide, (1) deep70"听70"108"
301348-7260(1) wide, (1) deep82"听听70"108"
301348-9660(2) wide, (1) deep106"听70"108"
301348-10860(2) wide, (1) deep118"听听70"108"
301348-60102(1) wide, (2) deep听70"112"听108"
301348-72102(1) wide, (2) deep82"听112"听108"听
301348-96102(2) wide, (2) deep106"112"听108"听
301348-108102(2) wide, (2) deep118"听112"听108"听

Loading Zone Dimensions
Description聽Pallet Capacity**LW贬听
301348-6060(1) wide, (1) deep60"60"108"听
301348-7260(1) wide, (1) deep72"60"听108"听
301348-9660(2) wide, (1) deep96"听60"听108"听
301348-10860(2) wide, (1) deep108"听60"听108"听
301348-60102(1) wide, (2) deep60"102"108"听
301348-72102(1) wide, (2) deep72"听102"听108"听
301348-96102(2) wide, (2) deep96"听102"听108"听
301348-108102(2) wide, (2) deep108"听102"听108"听
* Due to continuous improvement, specifications are subject to change without notice.
** Std. 48鈥漻 48鈥 pallet used for Pallet Capacity calculation.
  • Tracks and hardware zinc plated.
  • Gates are Powdercoated Yellow.
  • Top Rail Height = 42鈥
  • Lower Rail Height = 20"
  • Custom sizes also available.
Meets OSHA 1910.23(a) (8) and ANSI 6.4.3

For other relevant searches, you might want to try:

(00 73 19) Health and Safety Requirements
(05 52 00) Metal Railings
(05 52 13) Pipe and Tube Railings
(08 34 56) Security Gates
(10 22 16) Folding Gates
(10 40 00) Safety Specialties
(11 14 13.13) Portable Posts and Railings
  (11 24 29) Facility Fall Protection
(13 44 00) Modular Mezzanines
(32 31 00) Fences and Gates
(32 31 11) Gate Operators
(41 67 16) Plant Fall Protection Equipment
(41 67 19) Plant Safety Equipment